Технические параметры продукта
Standard:
| Standard | Description |
|---|
| ITU-TG.652 | Characteristics of a single mode optical fiber. |
| ITU-TG.655 | Characteristics of a non-zero dispersion -shifted single mode fibers optical. |
| EIA/TIA598 B | Col code of fiber optic cables. |
| IEC 60794-4-10 | Aerial optical cables along electrical power lines-family specification for OPGW. |
| IEC 60794-1-2 | Optical fiber cables -part test procedures. |
| IEEE1138-2009 | IEEE Standard for testing and performance for optical ground wire for use on electric utility power lines. |
| IEC 61232 | Aluminum -Clad steel wire for electrical purposes. |
| IEC60104 | Aluminum magnesium silicon alloy wire for overhead line conductors. |
| IEC 61089 | Round wire concentric lay overhead electrical stranded conductors. |
Colors -12 Chromatography:
| No. | 1 | 2 | 3 | 4 | 5 | 6 |
|---|
| Color | Blue | Orange | Green | Brown | Gray | White |
|---|
| No. | 7 | 8 | 9 | 10 | 11 | 12 |
|---|
| Color | Red | Black | Yellow | Violet | Pink | Aqua |
|---|
Technical Parameter:
Typical Design for Single Layer:
| Specification | Fiber Count | Diameter (mm) | Weight (kg/km) | RTS (KN) | Short Circuit (KA2s) |
|---|
| OPGW-32 (40.6;4.7) | 12 | 7.8 | 243 | 40.6 | 4.7 |
| OPGW-42 (54.0;8.4) | 24 | 9 | 313 | 54 | 8.4 |
| OPGW-42 (43.5;10.6) | 24 | 9 | 284 | 43.5 | 10.6 |
| OPGW-54 (55.9;17.5) | 36 | 10.2 | 394 | 67.8 | 13.9 |
| OPGW-61 (73.7;17.5) | 48 | 10.8 | 438 | 73.7 | 17.5 |
| OPGW-61 (55.1;24.5) | 48 | 10.8 | 358 | 55.1 | 24.5 |
| OPGW-68 (80.8;21.7) | 54 | 11.4 | 485 | 80.8 | 21.7 |
| OPGW-75 (54.5;41.7) | 60 | 12 | 459 | 63 | 36.3 |
| OPGW-76 (54.5;41.7) | 60 | 12 | 385 | 54.5 | 41.7 |
Typical Design for Double Layer:
| Specification | Fiber Count | Diameter (mm) | Weight (kg/km) | RTS (KN) | Short Circuit (KA2s) |
|---|
| OPGW-96 (121.7;42.2) | 12 | 13 | 671 | 121.7 | 42.2 |
| OPGW-127 (141.0;87.9) | 24 | 15 | 825 | 141 | 87.9 |
| OPGW-127 (77.8;128.0) | 24 | 15 | 547 | 77.8 | 128 |
| OPGW-145 (121.0;132.2) | 28 | 16 | 857 | 121 | 132.2 |
| OPGW-163 (138.2;183.6) | 36 | 17 | 910 | 138.2 | 186.3 |
| OPGW-163 (99.9;213.7) | 36 | 17 | 694 | 99.9 | 213.7 |
| OPGW-183 (109.7;268.7) | 48 | 18 | 775 | 109.7 | 268.7 |
| OPGW-183 (118.4;261.6) | 48 | 18 | 895 | 118.4 | 261.6 |
Описание продукта

Applications:
Основные особенности:
-
Малый диаметр кабеля, малый вес, низкая дополнительная нагрузка на башню;
-
Стальная труба находится в центре кабеля, второго механического усталостного повреждения нет.
-
Низкая устойчивость к боковому давлению, кручению и растяжению (однослойный).
Примечания:
Требования к деталям должны быть отправлены нам для проектирования кабеля и расчета цены. Ниже требования являются обязательными:
-
A, уровень напряжения линии электропередачи
-
B, количество волокон
-
К, чертеж структуры кабеля & диаметр
-
D, прочность на растяжение
-
F, емкость короткого замыкания
Тип испытания
Испытание типа может быть отменено путем подачи сертификата производителя на аналогичный продукт, выполненный в международно признанной независимой испытательной организации или лаборатории. Если испытание типа должно быть проведено, оно будет проведено в соответствии с дополнительной процедурой испытания типа, достигнутой по соглашению между покупателем и производителем.
Обычный тест
Коэффициент оптического затухания на всех длинах производственного кабеля измеряется в соответствии с IEC 60793-1-C1C (техника обратного рассеяния, OTDR). Стандартные одномодовые волокна измеряются на 1310 нм и на 1550 нм. Волокна с ненулевой дисперсией измеряются на 1550 нм.
Фабричный тест
Заводские приемочные испытания проводятся по два образца на заказ в присутствии заказчика или его представителя. Требования к качественным характеристикам определяются соответствующими стандартами и согласованными планами качества.

Packaging Requirements:
- 1:All cables shall be wound on treated wooden spools that are not returnable
- 2:Cable ends must be firmly secured to the spool and protected with waterproof shrink caps
- 3:Each spool must include: Protective plastic wrapping layer ,Reinforcing wooden slats for stability,Minimum 1m of free cable end for testing purposes, Standard spool length: 3000mm (±2% tolerance allowed)
Cable Identification:
The outer jacket must display:
- 1、Unique sequential numbering every 1m (±1% variance permitted)
- 2、 Additional repeating markings at 1m intervals showing: Product code and fiber count, Manufacturer identification, Production date (month/year),Total cable length
Standard Packaging Dimensions:
| Length | Container | Size (L×W×H) | Net Mass | Total Mass |
|---|
| 2 km | Wood spool | 90×75×90 cm | 156 kg | 220 kg |
| 3 km | Wood spool | 100×68×100 cm | 240 kg | 280 kg |
| 4 km | Wood spool | 109×75×109 cm | 300 kg | 368 kg |
| 5 km | Wood spool | 129×72×129 cm | 400 kg | 480 kg |
Technical Reference:
- 1、 Standard cable diameter: 10.0mm
- 2、Maximum span distance: 100m
- 3、Contact sales team for complete technical specifications
Spool Marking Standards:
Permanent markings (minimum 25-30mm height) must appear on both sides of each spool:
- 1、 Company name and trademark
- 2、Contained cable length
- 3、Cable specifications (type/fiber count)
- 4、Winding orientation
- 5、Weight measurements (gross/net)
Note: All wooden packaging materials must undergo proper fumigation treatment prior to use.
Case
Пример проекта связи в коридоре электропередачи в Анголе | Портфель поставок OPGW в качестве магистрали + оптоволоконный кабель для наружного применения
+
Турция: модернизация городской волоконной сети YRTFiber в Турции
+
Индонезия: модернизация городской сети YRTFiber в Индонезии
+
Замбия: Высокопроизводительный открытый волоконно-оптический кабель Поставка yrtfiber
+
YRFFIBER имеют в общей сложности 13 производственных линий, модернизированные беспыльные мастерские и высокопроизводительное технологическое оборудование. От закупки сырья до обработки готовой продукции, тестирования качества продукции, упаковки и экспорта, у нас есть полный спектр производственных линий. Ниже приведены некоторые из фактических фотографий мастерской

1. What is the OPGW-2 central stainless steel tube fiber cable used for?
OPGW-2 is designed for installation in high-voltage power transmission networks. It provides dual functionality: grounding protection and high-capacity fiber optic communication, making it ideal for utility and telecom applications.
2. What is the structure of this cable?
This cable uses a central stainless steel loose tube to house and protect the optical fibers. Surrounding layers typically include aluminum or aluminum-clad steel wires for mechanical strength and conductivity.
3. What fiber types and core counts are supported?
The OPGW-2 cable supports 12 to 144 fiber cores using G.652D or G.655C single-mode fibers, ensuring compatibility with modern communication systems and long-haul transmission.
4. What are the mechanical and environmental benefits of this design?
The stainless steel tube offers excellent crush resistance, corrosion protection, and thermal stability, while the outer layer provides electrical conductivity and grounding during lightning strikes.
5. What makes this cable suitable for aerial installation on power lines?
Its robust construction and dielectric protection allow for direct installation on overhead transmission towers, with no separate grounding wire needed. It resists EMI, lightning, and harsh weather conditions.